Search found 187 matches

by MD2020
Mon Nov 05, 2012 3:13 am
Forum: Crossing Signal Discussion
Topic: Huntsville, AL area railroad crossing signals
Replies: 66
Views: 49841

Re: Huntsville, AL area railroad crossing signals

Lets clairify a few things here: To "Pre-Empt" means to activate before . (Pre) To "Interconnect" means to connect together , IE, activate at the same time. Traffic signals are not truly pre-empted, unless there is a predictor unit inside the case with AX outputs to activate an outside source (Traff...
by MD2020
Mon Nov 05, 2012 2:59 am
Forum: Crossing Signal News
Topic: More WCH e-bells in Stoughton, MA...
Replies: 27
Views: 26431

Re: More WCH e-bells in Stoughton, MA...

Safetran is actually a leader in quality and sound output with E bells, but you don't see many of them, because of the circuitry inside, it makes them very expensive. (They have a verticle sense and a "Bell sense" feature that allows a crossing monitor to sense if the bell is working properly withou...
by MD2020
Sun Nov 04, 2012 5:12 pm
Forum: Crossing Signal News
Topic: More WCH e-bells in Stoughton, MA...
Replies: 27
Views: 26431

Re: More WCH e-bells in Stoughton, MA...

WCH E "bells" (sirens) sound awful anyway, and do not duplicate a bell sound, it is more like an alert siren. (When a real bell strikes, the tone/sound falls, a wch noisemaker strikes then ramps up, unlike any real bell) WCH mechanical bells, at least the ones made in the past several years, are che...
by MD2020
Sun Nov 04, 2012 11:33 am
Forum: Crossing Signal News
Topic: More WCH e-bells in Stoughton, MA...
Replies: 27
Views: 26431

Re: More WCH e-bells in Stoughton, MA...

Thats because anything made by WCH in the past several years is cheap junk.

I know firsthand, I am a signal maintainer, and I have to work with that junk sometimes.
by MD2020
Sat Oct 13, 2012 2:05 am
Forum: Crossing Signal Parts Request
Topic: Bracket needed
Replies: 26
Views: 23980

Re: Bracket needed

Don't talk bad about a DMD just because you're not familiar with it. They are built like a tank and will survive a lot of times where a PMD won't. If you know how to adjust one correctly, they will give you years of trouble free service. They perform just like a PMD, they are just not dominate on th...
by MD2020
Fri Oct 12, 2012 4:08 am
Forum: Crossing Signal Parts Request
Topic: Bracket needed
Replies: 26
Views: 23980

Re: Bracket needed

Oh yea, MI was some junk. I used to trash MI lightheads, until LED inserts became widespread. Now I save them, because they are excellent for installing LED inserts into. On that note, last set of WCH lightheads were falling apart in the installers hands, the pot metal was breaking on the elbow and ...
by MD2020
Thu Oct 11, 2012 1:32 pm
Forum: Crossing Signal Parts Request
Topic: Bracket needed
Replies: 26
Views: 23980

Re: Bracket needed

Nope, it was new from WCH, was in the brown box, straight from their factory, sir. I don't now how else to make it any more clear, their stuff is plain junk nowadays, I have 2 more they recently installed a few months ago that sound like they are going out as well.
by MD2020
Wed Oct 10, 2012 8:11 pm
Forum: Crossing Signal News
Topic: More WCH e-bells in Stoughton, MA...
Replies: 27
Views: 26431

Re: More WCH e-bells in Stoughton, MA...

We were discussing crossings with gates. Some Railroads have them just ring because it's a no-brainer. They don't have to configure the bell through the X relay or contacts in the gate mechanism, usually out of laziness. There is no real benefit to be offered to leave them ringing, just added annoya...
by MD2020
Wed Oct 10, 2012 3:24 pm
Forum: Crossing Signal News
Topic: More WCH e-bells in Stoughton, MA...
Replies: 27
Views: 26431

Re: More WCH e-bells in Stoughton, MA...

Your point?

A bell is warning that the crossing is activating, and the gates are descending. The train horn picks up audible warning after they are down, then there is no need for a bell any longer after that.
by MD2020
Wed Oct 10, 2012 9:48 am
Forum: Crossing Signal News
Topic: More WCH e-bells in Stoughton, MA...
Replies: 27
Views: 26431

Re: More WCH e-bells in Stoughton, MA...

Still doesn't make anything any safer.

And bells ringing upon gate rising is unsafe and a poor practice.